Design and Development of a Measuring Instrument for Cholesterol Level Detection in The Blood Using Non-Invasive Techniques Based on the Wemos D1 R1 Microcontroller
DOI:
https://doi.org/10.23960/jemit.213Abstract
Cholesterol level checks are generally performed either invasively or using a portable blood test strip. It requires a long laboratory analysis time and causes pain in the body, so a non-invasive tool is needed to check cholesterol levels. The study aims to detect cholesterol levels in the blood with a non-invasive technique based on the Wemos D1 R1 Microcontroller using the DS100A Oximeter Sensor. This tool is equipped with a Liquid Crystal Display (LCD) as a cholesterol level display and an LED light as a cholesterol level indicator that will light up red when cholesterol is high (>=240 mg/dL), light up yellow when cholesterol is at the high limit (200-239 mg/dL), and light up green when cholesterol is normal (<=200 mg/dL). Cholesterol level measurement is done by utilizing the red LED light emission on the sensor attached to the finger. Then, the photodiode will capture the light intensity from the red LED into a voltage value. A 10-bit ADC on the microcontroller then reads the voltage value. The ADC value was then converted into a cholesterol level in milligrams per deciliter (mg/dL) using a linear regression equation. The designed device is capable of detecting cholesterol levels in the range of 150-240 mg/dL. Test results indicate that the non-invasive cholesterol level test device has been successfully developed, with a precision of 98.85% and an error of 1.15%. Accuracy testing yielded a value of 97.14% with an error of 2.86%.
Downloads
References
Fitri, E. Y., & Maisoha, K. 2020. Uji Analisis Alat Ukur Non Invasive Real Time Kadar Kolesterol Darah. Seminar Nasional Keperawatan “Pemenuhan Kebutuhan Dasar Dalam Perawatan Paliatif Pada Era Normal Baru,” 1–
Humas BPJS. 2023. Laporan Pengelolaan Program dan Keuangan BPJS Kesehatan Tahun 2022
(Auditan). https://www.bpjs-kesehatan.go.id/bpjs/arsip/detail/2170. Diakses pada 21 Juli 2023.
Irwan. (2011). Epidemiologi Penyakit Tidak Menular. Deepublish. Yogyakarta.122 hlm.
KEMENKES. (2022). Kolesterol. https://yankes.kemkes.go.id. Diakses pada 1 Juni 2023.
Lopez, S. (2012). Pulse Oximeter Fundamentals and Design. Freescale Semiconductor. 1–39.
Marhaendrajaya, I., Hidayanto, E., Arifin, Z., & Sutanto, H. 2017. Desain dan realisasi alat pengukur kandungan kolesterol dalam darah non-invasive. Youngster Physics Journal, 6(3), 290–295.
Nurmar’atin, T. (2021). Deteksi Kadar Kolesterol Dalam Darah Secara Non Invasive Menggunakan Sistem Telemedika Berbasis IOT. Skripsi. Universitas Islam Negeri Walisongo. Semarang. 222 hlm.
P2PTM. (2019). Buku Pedoman Manajemen Penyakit Tidak Menular. Kementerian Kesehatan Republik Indonesia. Jakarta Selatan. 101 hlm.
Sucandra, M. A. K., & Astiti, N. K. A. P. (2016). Pulse Oximeter Generasi Terbaru. Fakultas Kedokteran Universitas Udayana. Bali. 11 hlm.
Downloads
Published
How to Cite
Issue
Section
License
Copyright (c) 2025

This work is licensed under a Creative Commons Attribution 4.0 International License.